AIR CONDITIONERS & ECONOMIZERS

Ultra-efficient Economizer Units that Consume Zero White Space and Allow More Power to IT

Cooling to Maximize Value for The Cloud

The Air Economizer is designed to scale with the growing demands of today’s data centers and helps save valuable white space. The efficient indirect air mode takes power that would be used for cooling and makes it available for data center operations. A polymer heat exchanger resists corrosion, and the unit’s modular design enables easy maintenance.

Using a polymer air-to-air heat exchanger to indirectly cool the data center and automatically switching between three modes of operation, the unit maximizes the efficiency of the cooling system while protecting the facility from outdoor contaminants.

Product Advantages & Benefits

1. Redundant Components – Single points of failure in the system have redundant components to maintain availability and reliability.

2. Active response control – Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided

3. Pre-engineered free-cooling system – Allows for fast design and installation with a Predesigned/Engineered package solution.

4. Pulse Powered Water Treatment System – Eliminates the use of chemicals in the system, allowing the water to be re-used or drained without harming the environment.

5. Green Refrigerant – Environmentally friendly refrigerant that can offer LEED points.

6. Operational Service – Allows critical components to be maintained/replaced while the system is in operation.

7. Easy service access – Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

8. Indirect Heat Exchange – A polymer heat exchanger allows the data center and outside airstreams to remain separated, thereby preventing contamination and humidity influences to the data center airstream.

9. Economization – Achieved by utilizing cool ambient air during winter months to take advantage of economizer hours and eliminating compressor operation.

10. Supplemental Mechanical Cooling – Provides extra capacity to augment economization, extending annual hours of energy savings.

11. Zero White Space – All cooling equipment is placed outside the data center, allowing for valuable white space to be fully utilized for IT equipment.

OVERCOME TRADITIONAL DATA CENTERS

Traditional data centers don’t deliver in today’s digital world ANYMORE. Transforming to modular-based data center facilities will help your service delivery, not only from your core data centers but also at the edge and for your distributed IT, or flexibly transform it into a DR Site with the lowest investment. You can achieve higher levels of flexibility, cost containment, and a more agile data center footprint for your on-premises service delivery model.