USDC Tech introduces micro-module data center for protect confidential information

Date:

Due to the needs of confidential information in business, the core data, network transmission, and core storage systems of enterprises require to operate safely and reliably. It is also more cautious in selecting data center infrastructure providers.

There are two important indicator requirements for the performance of the new data center: First, it must be stable, reliable, and highly safe; Second, it must meet the standard requirement for energy-saving. USDC Technology has introduced its current mainstream micro-module data center solution to satisfy those needs and solve the challenge of the green data center.

Taking into account high-security requirements, monitoring data platform, and the rapid growth of enterprises’ data in the next few years, USDC Technology has provided more reliable and scalable solutions in the design of the data center room infrastructure. The entire data center uses two sets of easy-to-do series micro-modules, including modular UPS, precision air-conditioning, and the data center infrastructure management (DCIM) system. All types of equipment are standardized products that comply with the industry’s specifications.

To meet the performance requirements of the enterprise users on the new data center, USDC Technology has adopting stable and reliable products and energy-saving solutions, including:

1. Scalability: Flexible in resizing and the micro-module design is best fit for the data center room under 10 racks.

2. Optimal cooling and power consumption: The PUE (Power Usage Effectiveness) level is controlled less than 1.6. The use of inter-row air-conditioning, direct air supply near the heat source, shorter airflow paths, and more precise cooling, which solves the problem of local hot spots.

3. The cold aisle is closed and isolated, and the airflow does not interfere with each other, avoiding the heat island effect and the loss of air volume and cooling capacity. Compared to the traditional computer room, energy-saving performance is much better.

4. Modular UPS: Adopts series of modular UPS, in case of a power module failure, it can automatically synchronize and automatically switch to the backup module to ensure continuous operation. The hot-swappable function and modules can improve the maintainability of the UPS system.

5. Tier III standards: All designs are N + 1, and meet the Tier III standards.

To provide better intelligent operation and maintenance of the data center, USDC Technology also provides the DCIM system, which integrates the four core systems – the rack space, power distribution, refrigeration, and access control in the same interface. The system is simple and easy to operate, which facilitates daily operation and maintenance. DCIM system improves the visibility of the actual capacity, demand situation that effectively reduces the downtime risks, makes full use of the available power, and reach the target of the upper limit capacity, reducing the cost of expanding new facilities.